Measuring Voltage with the 8 or 16 Channel Universal Input Touch Screen Data Loggers

The OM-DAQXL is an eight or 16 channel analog input portable data logger with a seven inch resistive touch-screen color display. Each input is programmable and can be configured for millivolts, milliamps, volts, strain gauge, thermocouple, thermistor, RTD or frequency. All the selections, menus, and configurations can be opened from the display touch screen. The unit also has four digital inputs, four alarm outputs, four digital outputs, one USB host port and one USB device port. The unit also has three LEDs for different indications (power, logging, and alarm).

The OM-DAQXL comes complete with protective rubber boot, 32 GB SD card, one plastic stylus, rechargeable lithium ion battery, 1 GB USB thumb drive, 1.8 m digital I/O cable, 1.8 m USB cable, AC power adaptor, screwdriver, alarm/excitation terminal block, set of 5 PTFE insulated Type K thermocouples, quick start guide, set of 5 ferrites to install on the thermocouple inputs (for noise reduction) and crimp-on earth terminal. The unit can be operated on a bench using the tilt stand or wall mounted using the given keyhole mount.

  • 7" touch screen TFT display
  • Benchtop or wall mount enclosure design
  • 8 or 16 virtual (maths) channels
  • 8 (OM-DAQXL-1) or 16 (OM-DAQXL-2) analog channel inputs
  • 8 digital I/O (4 Inputs, 4 Outputs)
  • 4 alarm outputs
  • Measures voltage, current, thermocouples, RTDS, thermistors, strain gauge, frequency and pulse
  • Fast sampling rate–125 samples/second (1 Channel)
  • 24-Bit analog input resolution
  • Large data storage: 1 GB internal memory, 32 GB SD card or 32 GB USB drive
  • USB device (PC communication) and USB host (USB drive, mouse, etc.)
  • Protective rubber boot - Comes with hard carrying case
  • Powers from rechargeable lithium-ion battery and/or AC adaptor

Home Screen

The home screen is the main screen of the data logger’s user interface. It is separated into three distinct sections.

Digital Display View

Status/information display: This status bar offers data such as battery charge percentage, lock/unlock data logger, system clock (displays current time and date), status of the four alarm outputs and logging mode indication.

Data Display Area: This is the area where different inputs (up to four channels) are displayed vs. time. The data is displayed in four different ways: Waveform, Table only, Waveform and Table, and Digital. In the digital view, each channel number and name are shown along with the value.

Navigation Toolbar: This toolbar gives access to all the tasks and menus of the data logger. Users can retract or extend the toolbar by pressing the Tool button.

Standalone Operation

The OM-DAQXL’s touch screen user interface (UI) makes configuring the data logger for operation straightforward and simple. Recorded data files can easily be reviewed and analyzed on the OM-DAQXL. For data analysis on a computer, just transfer the data file from the USB thumb drive or SD card to the PC and open the designated data file into Excel® or other data analysis software.

Specifications

  • Screen: 7 inch, TFT, resistive touch comes with plastic stylus
  • Rubber Boot: Black
  • Analogue Input Type: Thermocouple, thermistor, RTD, strain gauge, DC voltage, DC current
    • Thermocouple Types: J, K, T, E, R, S, B, C, N
      • Thermocouple Accuracy:
      • Type J or K: ±(0.15% of rdg + 1.1 °C)
      • Type T, E or N: ±(0.15% of rdg + 1.7 °C)
      • Type R, S, B or C: ±(0.15% of rdg + 2.0 °C)
    • RTD Types: Pt100, Pt500, Pt1000 (0.00385 or 0.00392 curve); 2, 3 or 4-wire
      • RTD Accuracy: ±(0.25% of rdg + 1 °C)
    • Thermistor Types: 2252 Ω/10 KΩ
      • Thermistor Accuracy: ±1.0 °C
    • DC Voltage Input Ranges: ±50 mV, ±100 mV, ±1 V, ±5 V, ±10 V, ±20 V, ±50 V
    • DC Current Input Range: ±20 mA
      • DC Voltage/Current Accuracy: ±0.1% of FS
    • Strain Gauge Type: 100 Ω full bridge, 350 Ω full bridge
      • Strain Gauge Excitation: 5 V, 10 V
  • Digital Input Type: Pulse/Frequency
    • Frequency/Pulse Input: 0 to 250 KHz
    • Frequency Accuracy: ±2 Hz
  • Sampling Rate: 125 s/sec (Max) to 1 s/hour (Min)
  • Maximum Sampling Rate per Number of Channels (Analogue and Digital):
    • 1 Channel: 125 s/sec
    • 2 Channels: 50 s/sec
    • 4 Channels: 25 s/sec
    • 8 Channels: 10 s/sec
    • 16 Channels: 5 s/sec
  • Logging Rate: 125 s/sec (Max) to 1 s/hour (Min)
  • Maximum Logging Rate per Number of Channels (Analogue and Digital):
    • 1 Channel: 125 s/sec
    • 2 Channels: 50 s/sec
    • 4 Channels: 25 s/sec
    • 8 Channels: 10 s/sec
    • 16 Channels: 5 s/sec
  • Excitation to Power External Transmitter: 24 Vdc @ 50 mA output–set in data session setting
  • Filter Options: Per channel selectable moving average filter: None, 2, 5, 10, 20 or 100 samples
  • Number of Samples for Moving Average Filter per Channel: Up to 50 samples
  • Maths (Virtual) Channels: 8 or 16
  • Digital Inputs: 4 Schmitt trigger based inputs
    • Range: 0 to 24 Vdc single-ended
    • Logic High Threshold: 2.5 V
    • Logic Low Threshold: 1.5 V
  • Digital Outputs: 4 channels, open collector, 5 V @ 50 mA
  • Alarm Output: 4, Open collector, 30 V @ 500 mA
  • Alarms per Channel: Two
  • Alarm Types: High, low, windows in, windows out, open sensor
  • Alarm Latching: Settable in alarm menu
  • On Alarm Event: Map to 4 alarm outputs, take screen shot, sound buzzer
  • Logging Conditions: On command or based on trigger conditions
  • Start and Stop Trigger Conditions: Timer, date and time, weekday and time, alarm output, external trigger
  • Memory:
    • Internal: 1 GB
    • SD Card: 32 GB
    • USB Drive: 32 GB
  • USB Ports: One host and one device
  • Battery: Rechargeable lithium-ion; 7.2 V @ 4.8 Ah
  • Battery Life: 4 to 8 hours based on display setting
  • DC Adaptor: 12 Vdc @ 5 A
  • Operating Environment: 0 to 50 °C, 0 to 95% RH non-condensing
  • General Dimensions: 28.6 L x 15.24 H x 6.35 cm D
  • Weight: 1.13 kg

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.