Posted in | Current Sensors

High-Performance Eddy-Current Displacement Sensor - ECL202 Series by Lion Precision

The Lion Precision ECL202 eddy-current displacement sensor provides highest precision with a digital core and push-button controls.

Key Features:

The product features of the ECL202 eddy-current displacement sensor are:

  • Linearity: ±0.2%
  • Resolution (typical):
    (Dependent on Probe and Range)
    • ECL202 Non-ferrous: 0.006% RMS
    • ECL202 Ferrous: 0.008% RMS
    • ECL202e: 0.2 µm RMS or higher
    • "Fine" ranges available for higher resolution
  • 0-10 VDC output
  • 15 kHz bandwidth
  • Push-button switch threshold (setpoint)
  • Push-button offset
  • Remote offset and threshold activation
  • Range indicating LEDs
  • Probes can be ordered as vacuum compatible
  • User-selectable bandwidth/resolution 100 Hz, 1 kHz, 10 kHz, 15 kHz
  • CE Compliant.

Specifications

The specifications of the ECL202 eddy-current displacement sensor are:

     
Resolution:
RMS, Typical

Dependent on probe and range.
ECL202 0.006% (Non-ferrous)
0.008% (Ferrous)
ECL202e Greater of 0.2 µm or
0.006% (Non-ferrous)
0.008% (Ferrous)
Linearity ±0.2% of Range
Error Band ±0.4% of Range
Bandwidth Selectable: 100 Hz, 1 kHz, 10 kHz, 15 kHz
Driver Temperature Drift
(15°C-50°C)

Typical. See Probe/Range chart for details.
 
Driver Temperature Drift
(15°C-50°C)

Typical. See Probe/Range chart for details.
±0.01% F.S./°C
Probe Temperature Drift
(15°C-65°C, except where noted)

Typical. See Probe/Range chart for details.
±0.01% F.S./°C
Analog Output 0-10 VDC, 0 Ù, 15 mA
Switched Output 30 VAC/60 VDC/100 mA
Input Power 12-24 VDC
1.9 W
Driver Operating Environment 4°C-50°C
IP40
Probe Operating Environment
Standard Probes come with PUR (Polyurethane) jacketed cables. High Temperature Probes have FEP jackets.
Other temperature ranges may be possible.
Standard Probes: IP67
High Temperature Probes: IP63
U3 Probe Standard Probe (PUR Cable):
-25°C to +125°C
(Available with optional FEP cable)
High Temperature Version Not Available
U5-18 Probes Standard Probes:
-25°C to +125°C
High Temperature Probes:
-25°C to +200°C
U25-50 Probes Standard Probes:
-25°C to +125°C
High Temperature Probes:
-25°C to +175°C

 

Other Equipment by this Supplier

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.