The Series 46 X capacitive transmitters available from Keller UK are integrated with the µP-electronics of the digital Series 30 pressure transmitters and features a ceramic measuring cell for low pressure ranges.
With the help of a polynomial compensation, the signal values of the temperature and pressure sensors are measured. Users can display and store the values on a personal computer and these values can be reprogrammed. The cable is equipped with a reference tube which links the sensor’s referential chamber to the ambient pressure.
Keller also offers an intrinsically safe version of pressure transmitter called Series 46 X Ei. The instrument can be employed in explosion-exposed environment where categories 1 and 2 are needed.
Specifications
The specifications of the Series 46 X capacitive transmitters are provided in the table below:
Pressure Ranges |
-30 mbar
100 mbar
300 mbar (relative) |
Error Band 10…50 °C |
0,1 % FS typ. / 0,2 % FS max. |
Output |
4...20 mA and 0...10 V |