New FCI Water & Wastewater Guide Explains How to Optimize Flow Measurement for Process Efficiency

Busy municipal water engineers will find that the new Water & Wastewater Treatment Guide from Fluid Components International (FCI) explains how to optimize flow measurement in 20 different municipal applications to enhance water and wastewater treatment process efficiency while also reducing operating costs at the same time.

Image Credit: Fluid Components International LLC

Whether a plant team is adding process measurements, replacing under-performing flow technologies, undertaking major automation upgrades, or designing new or expanded facilities, FCI has the right products for air/gas flow measurement, water/liquid/air/gas flow switching and alarms, and point level applications in municipal and industrial WWTP and WTP operations.

From wastewater aeration lines to digester gases, from potable water disinfection processes to pump flow protection, the right flow measurement instrumentation ensures optimal process operations and minimized maintenance that can save time and reduce expenses. With more than 10 unique and optimized flow measurement products, FCI has installed more air/gas flow meters and flow switch solutions in municipal wastewater and water treatment applications than any other supplier.

As a pioneer in thermal dispersion measurement technology, FCI thermal mass flow meters, thermal flow switches and level switches are the industry’s most recognized and installed throughout the world.  FCI developed and remains the leader in thermal flow sensing constant power technology, has innovated techniques such as equal mass sensor and is the sole provider of the industry’s Vortab® tab-type flow conditioners.

The simplicity and robustness of a thermal sensor in flow meter applications addresses many industrial technology concerns.  The sensor is comprised of two platinum RTDs that are protected within thermowells.  These sensors are typically fully welded to prevent migration of the measured gases into the instrument.  One RTD is heated while the other provides a reference by measuring the process temperature.  This temperature differential is directly proportional to the mass flow measurement of the process.

For example one of the industry’s newer renewable energy initiatives uses digester gas or biogas, which is measured with thermal flow meters, to help power co-generation and combined heat and power (CHP) systems. Depending upon the amount of digester gas or biogas produced at any given time, a supplemental supply of natural gas (NG) can be required. It is essential to understand the calorific value of the digester gas feed in order to supplement it with the correct amount of NG, maintaining a proper ratio to ensure the calorific value of the blended gas being fed to the engine ensures efficient, continuous operation.

In co-generation and CHP systems, thermal mass flow measurements maintain this proper ratio in order to achieve higher energy efficiencies. Capacity demand requires instrumentation with flow turndown capabilities as high as 100:1. Gas specific calibrations ensure overall performance of the mass flow meter under actual field conditions. The use of FCI flow conditioners allows for reducing the footprint of meter runs in older crowded plants.

FCI’s global product and service support, along with local agency approvals, certifications, and compliance is further assurance that water and wastewater treatment plants can rely on FCI instrumentation in their facilities wherever they are located. With products in continuous operation in water treatment facilities for 30 years and longer, FCI assures users of the highest quality, lowest maintenance, longest service life, and peerless expertise to maximize their instrumentation investment

Fluid Components International is a global company committed to meeting the needs of its customers through innovative solutions for the most challenging requirements for sensing, and measuring the flow, pressure and temperature of gases.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Fluid Components International LLC. (2021, October 26). New FCI Water & Wastewater Guide Explains How to Optimize Flow Measurement for Process Efficiency. AZoSensors. Retrieved on December 03, 2024 from https://www.azosensors.com/news.aspx?newsID=14779.

  • MLA

    Fluid Components International LLC. "New FCI Water & Wastewater Guide Explains How to Optimize Flow Measurement for Process Efficiency". AZoSensors. 03 December 2024. <https://www.azosensors.com/news.aspx?newsID=14779>.

  • Chicago

    Fluid Components International LLC. "New FCI Water & Wastewater Guide Explains How to Optimize Flow Measurement for Process Efficiency". AZoSensors. https://www.azosensors.com/news.aspx?newsID=14779. (accessed December 03, 2024).

  • Harvard

    Fluid Components International LLC. 2021. New FCI Water & Wastewater Guide Explains How to Optimize Flow Measurement for Process Efficiency. AZoSensors, viewed 03 December 2024, https://www.azosensors.com/news.aspx?newsID=14779.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.