Advancing Intravascular Gas Monitoring with a Miniaturized Spectrometer

In a recent article published in the journal Science Robotics, researchers developed a miniaturized all-fiber photoacoustic spectrometer (FPAS) that promises to transform intravascular gas monitoring.

Traditional spectroscopy systems, while effective, are often bulky and impractical for applications requiring minimal invasiveness, such as medical diagnostics. The FPAS addresses these limitations by offering a compact solution as a gas sensor capable of detecting trace gas concentrations at parts-per-billion (ppb) levels.

This innovation is particularly significant for continuous monitoring of gases in medical settings, where real-time data can enhance patient care and treatment outcomes.​​​​​​​

Medical, research and scientist in laboratory with microscope, observation and experiment for study.
Study: Microscale fiber photoacoustic spectroscopy for in situ and real-time trace gas sensing. Image Credit: PeopleImages.com - Yuri A/Shutterstock.com

​​​​​​​​​​​​​Background

Spectroscopy is a powerful analytical technique used to identify and quantify substances based on their interaction with light. Conventional laser spectroscopy systems typically rely on large components, including light sources, mirrors, and gas cells, which can hinder their application in confined spaces.

In the medical field, especially for intravascular diagnostics, the need for compact and efficient systems is paramount. The FPAS, developed in this work represents a significant leap forward in the field of gas sensors.

Photoacoustic spectroscopy (PAS) detects sound waves produced by gas molecules absorbing modulated light. Leveraging this principle, the FPAS offers exceptional sensitivity and fast response times, all within a compact design.

The Current Study

The design of the FPAS incorporates several innovative features that contribute to its compactness and efficiency. The system employs a fiber-optic configuration, allowing both the pump and probe light beams to be delivered through the same fiber.

This eliminates the need for bulky free-space optics, which are common in traditional setups of gas sensors. The fiber-optic cavity measures only 60 micrometers in length and 125 micrometers in diameter, making it remarkably small.

The FPAS, though compact in size, achieves an acetylene gas detection limit as low as 9 ppb, showcasing a sensitivity level on par with larger laboratory spectrometers.

The operational principle of the FPAS is based on the generation of photoacoustic signals. When gas molecules absorb modulated light, they undergo thermal expansion, producing sound waves that can be detected and analyzed.

This method allows for ultrafast measurements, with response times as quick as 18 milliseconds, significantly faster than conventional photoacoustic systems. The researchers successfully tested the FPAS in various scenarios, including monitoring carbon dioxide (CO2) concentrations in flowing gas, detecting fermentation in yeast solutions with sample volumes as small as 100 nanoliters, and tracking dissolved CO2 levels in rat blood vessels in vivo.

The spectrometer was inserted into the tail vein of rats via a syringe, enabling real-time monitoring of blood gas levels under different physiological conditions.

Results and Discussion

The results of the study highlight the FPAS's potential for real-time intravascular gas monitoring. The system effectively measured CO2 levels in rat blood under hypoxic (low oxygen) and hypercapnic (high CO2) conditions, showcasing its capability to provide critical data without the need for invasive blood sample collection. This feature is particularly advantageous in clinical settings, where minimizing patient discomfort and risk is essential.

The FPAS's ability to operate with small sample volumes and deliver rapid results positions it as a valuable tool for various applications beyond intravascular diagnostics. For instance, its sensitivity and speed make it suitable for monitoring the health of lithium-ion batteries, where timely detection of gas emissions can prevent failures and enhance safety.

Additionally, the compact design allows for integration with existing fiber-optic networks, making the FPAS a cost-effective solution for remote detection of hazardous gases in confined spaces, such as industrial environments.

The study also emphasizes the importance of the FPAS in advancing the field of biomedical diagnostics. By providing continuous, real-time data on gas concentrations, the spectrometer can facilitate better decision-making in patient care.

The ability to monitor blood gases non-invasively opens new avenues for managing respiratory conditions, metabolic disorders, and other health issues that require close monitoring of gas levels.

Conclusion

In conclusion, the miniaturized all-fiber photoacoustic spectrometer represents a significant advancement in the field of spectroscopy, particularly for applications requiring minimal invasiveness, such as intravascular gas monitoring.

Its compact design, high sensitivity, and rapid response times make it a promising tool for real-time diagnostics in medical settings. The successful demonstration of the FPAS in monitoring CO2 levels in vivo underscores its potential to enhance patient care by providing critical data without the need for invasive procedures.

Furthermore, the versatility of the FPAS extends beyond healthcare, with applications in industrial monitoring and environmental safety.

As research continues to refine and expand the capabilities of this technology, the FPAS is poised to play a crucial role in the future of both medical diagnostics and broader scientific applications.

Journal Reference

Hong H. et al. (2025).  Imaging-guided bioresorbable acoustic hydrogel microrobots. Science Robotics 9, eadp3593. doi:10.1126/scirobotics.adp3593. https://www.science.org/doi/10.1126/scirobotics.adp3593

Dr. Noopur Jain

Written by

Dr. Noopur Jain

Dr. Noopur Jain is an accomplished Scientific Writer based in the city of New Delhi, India. With a Ph.D. in Materials Science, she brings a depth of knowledge and experience in electron microscopy, catalysis, and soft materials. Her scientific publishing record is a testament to her dedication and expertise in the field. Additionally, she has hands-on experience in the field of chemical formulations, microscopy technique development and statistical analysis.    

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Jain, Noopur. (2025, January 08). Advancing Intravascular Gas Monitoring with a Miniaturized Spectrometer. AZoSensors. Retrieved on January 09, 2025 from https://www.azosensors.com/news.aspx?newsID=16155.

  • MLA

    Jain, Noopur. "Advancing Intravascular Gas Monitoring with a Miniaturized Spectrometer". AZoSensors. 09 January 2025. <https://www.azosensors.com/news.aspx?newsID=16155>.

  • Chicago

    Jain, Noopur. "Advancing Intravascular Gas Monitoring with a Miniaturized Spectrometer". AZoSensors. https://www.azosensors.com/news.aspx?newsID=16155. (accessed January 09, 2025).

  • Harvard

    Jain, Noopur. 2025. Advancing Intravascular Gas Monitoring with a Miniaturized Spectrometer. AZoSensors, viewed 09 January 2025, https://www.azosensors.com/news.aspx?newsID=16155.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.